FIRMWARE CHANGES 29412: - Added input Operation.ShadowMode bit to indicate when the regulator is working in shadow (1) or normal (0) 29295: - Added support for Concurrent CPU - Disable NCC when Bottom Limit Switch is active - Added RegStatus ControlPowerProgramPercent (400673) and ControlSmartARCPercent (400674) for Modbus map publishing - Fixed alarm timing problem for PLC Not active, SmartARC not active, Local I/O fault and Short Electrode. Real timing was triple the configured unless a user saved the AlarmLimits model - Fixed FiringCircuitReplacement unable to reconnect after trying 120 times. - Updated documentation: RegStatus ControlPowerProgramPercent and ControlSmartARCPercent; Operation.ChargePowerOnTime_Offset units and divisor; SmartARCSupport.* divisors 28281: -Added FCR Modbus Address Offset 26077: - Updated the Dynamic NCC logic, now supports DynNCCMinPressure, DynNCCMaxPressure and EnableNCCDynamicOffline special variables - Fixed End of charge input from SmartARC 25597: - Fixed the Nexus reconnection logic, it stopped trying after a long unsuccessful period 25299: - AutoLower has a delayed start (OnDelay) - AutoLower overrides the Vsp & Isp 24834: - Fixed incorrect fatal error. 24330: - Fixed memory corruption occurring when an HMI was closed or lost its connection, and a user saves the model in the FurnaceType screen. 23611: - Added UseFastRaise, Speed and Ramp properties to ShaperGains __________________________________________________________________________________________ HMI CHANGES 29473: - Added support for hiding the HMI when operating in Shadow mode and showing it when being active (General Settings), useful when there are multiple controllers 29297: - Updated documentation: RegStatus ControlPowerProgramPercent and ControlSmartARCPercent; Operation.ChargePowerOnTime_Offset units and divisor; SmartARCSupport.* divisors 29031: - Fixed IOConfiguration voltage divider R2 control that was being hidden incorrectly on single electrode furnaces 28280: - Added Electrical System - FCR Modbus Address Offset 26223: - Fixed online help and updated Auto Lower text and images - Fixed bug that caused exported files miss columns containing tag or id, like Voltage - Added missing AdvancedControlProfile column to Heat Report 25993: - Added balance column to statistics dialog - Fixed a potential model corruption in the model Undo button - Fixed External Data loading issues 25680: - Improved the Electrode Tests information gathering to prevent incomplete test packagess. 25481: - Fixed display Dynamic NCC Setpoint scale. The scale adjustment depends on Min and Max pressures at the Analog Inputs. - Improvement at Proxy Service, after save Network Settings the service is reconfigured automatically in order to let other services (Trends & HMI) communicate with QNX. 25299: - Added CurrentSetpoint and ActionDelay to AutoLower Model Isp and OnDelay added. - Screen layout improved. Units labels corrected. - ReSized the Color Boxes for selecting the color of the trend - Improved upgarde time to be applied 23812: - Fixes to LEDs (Auto, JS Raise, JS Lower) on twin shells without independent electrodes - Added Invert setting to Encoder channel - Fixed bug in Furnace Type that prevented it from being saved 23611: - Shaper Screen - Speed, Ramp and enable checkbox for FastRaise - Spanish translation - Shaper Screen - Speed, Ramp and enable checkbox for FastRaise